For a longstanding customer in southern Germany, recurring ash and slag build-up in critical boiler areas had become a persistent maintenance challenge. Saint-Gobain Performance Ceramics & Refractories worked with the customer to adapt its T-Clip® PRO solution to the specific conditions of the plant, combining standard system benefits with customized tile geometries.
How a Customized Refractory Design Eliminated Ash Accumulation in a Waste Incineration Boiler
The Challenge
The customer was facing two main issues inside the boiler:
- In the nose area and ignition hood, slag and ash were accumulating on the lining, requiring work during every maintenance shutdown where conventional mixes had previously been used.
- At the transition between the grate and the side walls, a step in the lining encouraged ash build-up. This area was also exposed to severe wear conditions around the main combustion zone.
The objective was therefore not only to protect the boiler surfaces, but also to improve the geometry of these critical areas and reduce recurring maintenance needs.
A Tailored T-Clip® PRO Solution
To address the first challenge, the customer installed T-Clip® PRO tiles on the ignition hood and curved tiles in the nose area.
For the grate-to-side-wall transition, Saint-Gobain developed a thicker 70 mm T-Clip® PRO tile. The customized thickness created a flatter transition between the grate and the side wall, eliminating the step where ash had previously accumulated.
The additional material thickness was also designed to provide more material in the area exposed to the demanding conditions of the main fire zone.
Results After One Year in Operation
After one year of service, the customer reported clear improvements:
- Less ash sticking in the nose area and ignition hood.
- No maintenance required in these areas after one year of operation.
- No ash build-up at the transition between the grate and side wall following installation of the customized 70 mm tiles.
- The thicker tiles showed wear comparable to the surrounding bricks, while providing additional material to withstand the severe operating conditions.
These results demonstrate how adapting refractory geometry to the actual boiler configuration can help address localized operational challenges while supporting more efficient maintenance.
Engineering Solutions Around the Customer’s Boiler
T-Clip® PRO is designed to protect Waste-to-Energy boiler tube walls against aggressive operating conditions. Its adjustable fixing concept and availability of special tile sizes allow the system to be adapted to different boiler positions and geometries.
In this project, the combination of curved tiles and a customized 70 mm T-Clip® PRO tile illustrates Saint-Gobain’s ability to go beyond a standard product approach and develop a solution around a customer’s specific operational needs.
Every Waste-to-Energy boiler presents different operating conditions and wear patterns. By combining material expertise, application engineering and adaptable refractory systems, Saint-Gobain works with customers to develop solutions for their specific challenges.